Parameter | Value | Notes |
---|---|---|
Snow load, kg/m² | 490 | 7th snow area |
Wind load, kg/sqm | 85 | 7th wind region |
Seismic load, points | 9 | |
Operating temperature range, °С | -40…+45 | |
Thermal insulator | Polyisocyanurate foam, density 38–42 kg/m³ | In wall sandwich panels |
Thermal conductivity, W/(m K) | 0,022 | For sandwich panels with PIR filler |
Combustibility class according to European Standards | G1 (low-flammable materials) | For sandwich panels with PIR filler |
Fire resistance limit, min | EI45 | For sandwich panels with PIR filler |
1. People who have studied this manual are allowed to operate the EFFECT LIGHT house kit.
2. It is not allowed to attach equipment, engineering systems, furniture and various devices to structures and elements of the house kit in places not provided for in the working documentation or operating instructions.
3. It is prohibited to independently make changes to the design of the components of the house kit and install additional equipment.
4. It is prohibited to carry out processing (drilling, cutting, etc.) of painted steel structures of the house kit, which damage the paint and varnish coating. The operating conditions of the house kit must comply with GOST 22853-86. Operating air temperature values during operation must comply with GOST 22853-86: from -40 to +45 °C.
5. It is prohibited to operate the house without ventilation.
6. During operation, preventive inspections, maintenance and repairs should be carried out in accordance with the operation manual. It is allowed to repair paintwork damaged during transportation of products, loading and unloading or construction and installation works, using repair materials similar to the materials of the main coating.
7. Installation of home-made heating and electric heating devices and appliances in the house kit is not allowed.
7. Installation of home-made heating and electric heating devices and appliances in the house kit is not allowed.
9. During operation of the house kit, it must be equipped with fire extinguishing means.
10. It is prohibited to place sources of open fire in close proximity to the house kit.
Packing in cardboard | Packaging features |
---|---|
Description | Cardboard sheets are placed on the floor finish to protect it; When packing transport packages (transpacks), cardboard sheets are laid between blank wall sandwich panels to prevent damage to their coating |
Packing in bubble wrap | Packaging features |
---|---|
Description | Protective coating for the block container and transport package |
Packing in container | Packaging features |
---|---|
Description | Complete set of block containers placed in a standard transport container |
Packing in cardboard box | Packaging features |
---|---|
Description | The packaging is a standard size box |
Contents | Three-layer cardboard box, stretch film, adhesive tape with logo |
Width, mm | 700 |
Height, mm | 900 |
Length, mm | 1 400 |
Packing in stretch film | Packaging features |
---|---|
Description | Covering the front surface of the steel structures of the block container with protective adhesive tape to prevent damage to the paintwork |
Packing on pallet | Packaging features |
---|---|
Description | Wooden frame for transporting additional steel structures of modular buildings (additional roof, porch, canopies, stairs, etc.) |
Assembly instructions for EFFECT house kits
Operating instructions for EFFECT house kits
Project of work production
Transport diagrams LIGHT 44
Technical data sheet EFFECT LIGHT 44
Sanitary and epidemiological examination
Thermal calculation
Project EFFECT LIGHT 44
EFFECT LIGHT 44_1.1_General data. List of sheets
EFFECT LIGHT 44_1.2_Specification of doors and windows
EFFECT LIGHT 44_1.3_Specification of sockets and switches
EFFECT LIGHT 44_2_Installation plan
EFFECT LIGHT 44_3_Plan with furniture arrangement
EFFECT LIGHT 44_4_Facade
EFFECT LIGHT 44_5.1_Exterior visualization. View 1
EFFECT LIGHT 44_5.2_Exterior visualization. View 2
EFFECT LIGHT 44_5.3_Interior visualization. View 1
EFFECT LIGHT 44_5.4_Interior visualization. View 2
EFFECT LIGHT 44_5.5_Interior visualization. View 3
EFFECT LIGHT 44_5.6_Interior visualization. View 4
EFFECT LIGHT 44_5.7_Interior visualization. View 5
EFFECT LIGHT 44_6_Ceiling plan with reference to lighting fixtures
EFFECT LIGHT 44_7_Scheme for switching on lighting devices
EFFECT LIGHT 44_8_Switch assignment plan
EFFECT LIGHT 44_9_Socket assignment plan
EFFECT LIGHT 44_10_Utility networks 1
EFFECT LIGHT 44_11_Utility networks 2
EFFECT LIGHT 44_12_Utility networks 3
Mounting diagram of the visor, 100 mm panel
Mounting diagram of the visor, panel 120 mm
Mounting diagram of the visor, panel 150 mm
Porch mounting diagram_height 440 mm
Porch mounting diagram_height 660 mm
Installation diagram of the EFFECT LIGHT staircase
Soft roof EFFECT LIGHT 44_88, insulation thickness 50 mm
Soft roof EFFECT LIGHT 44_88, insulation thickness 100 mm
Soft roof EFFECT LIGHT 44_88, insulation thickness 150 mm
Soft roof EFFECT LIGHT 44_88, insulation thickness 200 mm
Soft roof EFFECT LIGHT 44_88 with slope
The warranty period is calculated from the date of signing the universal transfer documents and is 5 years, provided that the consumer complies with all rules of operation, transportation, storage and installation.
Complaints can be made during the warranty period, provided that the consumer complies with the requirements of the instructions for operating the building with the drawing up of a claim statement containing:
• the name of the organization in which the building is operated, its postal address,
• the date of receipt of the building from manufacturer,
• nature of the damage and the conditions under which it occurred,
• conclusion of the commission with the participation of a representative of the interested party.
Changes to the design of the EFFECT house kit not agreed with the supplier are not covered by the supplier's warranty.
Parameter | Value | Notes |
---|---|---|
Snow load, kg/m² | 490 | 7th snow area |
Wind load, kg/sqm | 85 | 7th wind region |
Seismic load, points | 9 | |
Operating temperature range, °С | -40…+45 | |
Thermal insulator | Polyisocyanurate foam, density 38–42 kg/m³ | In wall sandwich panels |
Thermal conductivity, W/(m K) | 0,022 | For sandwich panels with PIR filler |
Combustibility class according to European Standards | G1 (low-flammable materials) | For sandwich panels with PIR filler |
Fire resistance limit, min | EI45 | For sandwich panels with PIR filler |
1. People who have studied this manual are allowed to operate the EFFECT LIGHT house kit.
2. It is not allowed to attach equipment, engineering systems, furniture and various devices to structures and elements of the house kit in places not provided for in the working documentation or operating instructions.
3. It is prohibited to independently make changes to the design of the components of the house kit and install additional equipment.
4. It is prohibited to carry out processing (drilling, cutting, etc.) of painted steel structures of the house kit, which damage the paint and varnish coating. The operating conditions of the house kit must comply with GOST 22853-86. Operating air temperature values during operation must comply with GOST 22853-86: from -40 to +45 °C.
5. It is prohibited to operate the house without ventilation.
6. During operation, preventive inspections, maintenance and repairs should be carried out in accordance with the operation manual. It is allowed to repair paintwork damaged during transportation of products, loading and unloading or construction and installation works, using repair materials similar to the materials of the main coating.
7. Installation of home-made heating and electric heating devices and appliances in the house kit is not allowed.
7. Installation of home-made heating and electric heating devices and appliances in the house kit is not allowed.
9. During operation of the house kit, it must be equipped with fire extinguishing means.
10. It is prohibited to place sources of open fire in close proximity to the house kit.
Packing in cardboard | Packaging features |
---|---|
Description | Cardboard sheets are placed on the floor finish to protect it; When packing transport packages (transpacks), cardboard sheets are laid between blank wall sandwich panels to prevent damage to their coating |
Packing in bubble wrap | Packaging features |
---|---|
Description | Protective coating for the block container and transport package |
Packing in container | Packaging features |
---|---|
Description | Complete set of block containers placed in a standard transport container |
Packing in cardboard box | Packaging features |
---|---|
Description | The packaging is a standard size box |
Contents | Three-layer cardboard box, stretch film, adhesive tape with logo |
Width, mm | 700 |
Height, mm | 900 |
Length, mm | 1 400 |
Packing in stretch film | Packaging features |
---|---|
Description | Covering the front surface of the steel structures of the block container with protective adhesive tape to prevent damage to the paintwork |
Packing on pallet | Packaging features |
---|---|
Description | Wooden frame for transporting additional steel structures of modular buildings (additional roof, porch, canopies, stairs, etc.) |
The warranty period is calculated from the date of signing the universal transfer documents and is 5 years, provided that the consumer complies with all rules of operation, transportation, storage and installation.
Complaints can be made during the warranty period, provided that the consumer complies with the requirements of the instructions for operating the building with the drawing up of a claim statement containing:
• the name of the organization in which the building is operated, its postal address,
• the date of receipt of the building from manufacturer,
• nature of the damage and the conditions under which it occurred,
• conclusion of the commission with the participation of a representative of the interested party.
Changes to the design of the EFFECT house kit not agreed with the supplier are not covered by the supplier's warranty.
Technical data sheet EFFECT LIGHT 44
Sanitary and epidemiological examination
Thermal calculation
Project EFFECT LIGHT 44
EFFECT LIGHT 44_1.1_General data. List of sheets
EFFECT LIGHT 44_1.2_Specification of doors and windows
EFFECT LIGHT 44_1.3_Specification of sockets and switches
EFFECT LIGHT 44_2_Installation plan
EFFECT LIGHT 44_3_Plan with furniture arrangement
EFFECT LIGHT 44_4_Facade
EFFECT LIGHT 44_5.1_Exterior visualization. View 1
EFFECT LIGHT 44_5.2_Exterior visualization. View 2
EFFECT LIGHT 44_5.3_Interior visualization. View 1
EFFECT LIGHT 44_5.4_Interior visualization. View 2
EFFECT LIGHT 44_5.5_Interior visualization. View 3
EFFECT LIGHT 44_5.6_Interior visualization. View 4
EFFECT LIGHT 44_5.7_Interior visualization. View 5
EFFECT LIGHT 44_6_Ceiling plan with reference to lighting fixtures
EFFECT LIGHT 44_7_Scheme for switching on lighting devices
EFFECT LIGHT 44_8_Switch assignment plan
EFFECT LIGHT 44_9_Socket assignment plan
EFFECT LIGHT 44_10_Utility networks 1
EFFECT LIGHT 44_11_Utility networks 2
EFFECT LIGHT 44_12_Utility networks 3
Mounting diagram of the visor, 100 mm panel
Mounting diagram of the visor, panel 120 mm
Mounting diagram of the visor, panel 150 mm
Porch mounting diagram_height 440 mm
Porch mounting diagram_height 660 mm
Installation diagram of the EFFECT LIGHT staircase
Soft roof EFFECT LIGHT 44_88, insulation thickness 50 mm
Soft roof EFFECT LIGHT 44_88, insulation thickness 100 mm
Soft roof EFFECT LIGHT 44_88, insulation thickness 150 mm
Soft roof EFFECT LIGHT 44_88, insulation thickness 200 mm
Soft roof EFFECT LIGHT 44_88 with slope